Measurement
Create Function
Input Parameters
net.measurement
Parameter |
Datatype |
Value Range |
Explanation |
type |
string |
“p”
“q”
“i”
“v”
|
Defines what physical quantity is measured |
element_type |
string |
“bus”
“line”
“transformer”
|
Defines which element type is equipped with the measurement |
value |
float |
Measurement value |
|
std_dev |
float |
Standard deviation (same unit as measurement) |
|
bus |
int |
must be in
net.bus.index
|
Defines the bus at which the measurement is placed. For line or transformer measurement it defines the side at which the measurement is placed (from_bus or to_bus). |
element |
int |
must be in
net.line.index or
net.trafo.index
|
If the element_type is “line” or “transformer”, element is the index of the relevant element. For “bus” measurements it is None (default) |
check_existing |
bool |
Checks if a measurement of the type already exists and overwrites it. If set to False, the measurement may be added twice (unsafe behaviour), but the performance increases |
|
index |
int |
Defines a specific index for the new measurement (if possible) |