Basic Standard Types

Every pandapower network comes with a default set of standard types.

Note

The pandapower standard types are compatible with 50 Hz systems, please be aware that the standard type values might not be realistic for 60 Hz (or other) power systems.

Lines

r_ohm_per_km

x_ohm_per_km

c_nf_per_km

max_i_ka

type

q_mm2

alpha

NAYY 4x50 SE

0.642

0.083

210.0

0.142

cs

50

0.00403

NAYY 4x120 SE

0.225

0.08

264.0

0.242

cs

120

0.00403

NAYY 4x150 SE

0.208

0.08

261.0

0.27

cs

150

0.00403

NA2XS2Y 1x95 RM/25 12/20 kV

0.313

0.132

216.0

0.252

cs

95

0.00403

NA2XS2Y 1x185 RM/25 12/20 kV

0.161

0.117

273.0

0.362

cs

185

0.00403

NA2XS2Y 1x240 RM/25 12/20 kV

0.122

0.112

304.0

0.421

cs

240

0.00403

NA2XS2Y 1x95 RM/25 6/10 kV

0.313

0.123

315.0

0.249

cs

95

0.00403

NA2XS2Y 1x185 RM/25 6/10 kV

0.161

0.11

406.0

0.358

cs

185

0.00403

NA2XS2Y 1x240 RM/25 6/10 kV

0.122

0.105

456.0

0.416

cs

240

0.00403

NA2XS2Y 1x150 RM/25 12/20 kV

0.206

0.116

250.0

0.319

cs

150

0.00403

NA2XS2Y 1x120 RM/25 12/20 kV

0.253

0.119

230.0

0.283

cs

120

0.00403

NA2XS2Y 1x70 RM/25 12/20 kV

0.443

0.132

190.0

0.22

cs

70

0.00403

NA2XS2Y 1x150 RM/25 6/10 kV

0.206

0.11

360.0

0.315

cs

150

0.00403

NA2XS2Y 1x120 RM/25 6/10 kV

0.253

0.113

340.0

0.28

cs

120

0.00403

NA2XS2Y 1x70 RM/25 6/10 kV

0.443

0.123

280.0

0.217

cs

70

0.00403

N2XS(FL)2Y 1x120 RM/35 64/110 kV

0.153

0.166

112.0

0.366

cs

120

0.00393

N2XS(FL)2Y 1x185 RM/35 64/110 kV

0.099

0.156

125.0

0.457

cs

185

0.00393

N2XS(FL)2Y 1x240 RM/35 64/110 kV

0.075

0.149

135.0

0.526

cs

240

0.00393

N2XS(FL)2Y 1x300 RM/35 64/110 kV

0.06

0.144

144.0

0.588

cs

300

0.00393

15-AL1/3-ST1A 0.4

1.8769

0.35

11.0

0.105

ol

16

0.00403

24-AL1/4-ST1A 0.4

1.2012

0.335

11.25

0.14

ol

24

0.00403

48-AL1/8-ST1A 0.4

0.5939

0.3

12.2

0.21

ol

48

0.00403

94-AL1/15-ST1A 0.4

0.306

0.29

13.2

0.35

ol

94

0.00403

34-AL1/6-ST1A 10.0

0.8342

0.36

9.7

0.17

ol

34

0.00403

48-AL1/8-ST1A 10.0

0.5939

0.35

10.1

0.21

ol

48

0.00403

70-AL1/11-ST1A 10.0

0.4132

0.339

10.4

0.29

ol

70

0.00403

94-AL1/15-ST1A 10.0

0.306

0.33

10.75

0.35

ol

94

0.00403

122-AL1/20-ST1A 10.0

0.2376

0.323

11.1

0.41

ol

122

0.00403

149-AL1/24-ST1A 10.0

0.194

0.315

11.25

0.47

ol

149

0.00403

34-AL1/6-ST1A 20.0

0.8342

0.382

9.15

0.17

ol

34

0.00403

48-AL1/8-ST1A 20.0

0.5939

0.372

9.5

0.21

ol

48

0.00403

70-AL1/11-ST1A 20.0

0.4132

0.36

9.7

0.29

ol

70

0.00403

94-AL1/15-ST1A 20.0

0.306

0.35

10.0

0.35

ol

94

0.00403

122-AL1/20-ST1A 20.0

0.2376

0.344

10.3

0.41

ol

122

0.00403

149-AL1/24-ST1A 20.0

0.194

0.337

10.5

0.47

ol

149

0.00403

184-AL1/30-ST1A 20.0

0.1571

0.33

10.75

0.535

ol

184

0.00403

243-AL1/39-ST1A 20.0

0.1188

0.32

11.0

0.645

ol

243

0.00403

48-AL1/8-ST1A 110.0

0.5939

0.46

8.0

0.21

ol

48

0.00403

70-AL1/11-ST1A 110.0

0.4132

0.45

8.4

0.29

ol

70

0.00403

94-AL1/15-ST1A 110.0

0.306

0.44

8.65

0.35

ol

94

0.00403

122-AL1/20-ST1A 110.0

0.2376

0.43

8.5

0.41

ol

122

0.00403

149-AL1/24-ST1A 110.0

0.194

0.41

8.75

0.47

ol

149

0.00403

184-AL1/30-ST1A 110.0

0.1571

0.4

8.8

0.535

ol

184

0.00403

243-AL1/39-ST1A 110.0

0.1188

0.39

9.0

0.645

ol

243

0.00403

305-AL1/39-ST1A 110.0

0.0949

0.38

9.2

0.74

ol

305

0.00403

490-AL1/64-ST1A 110.0

0.059

0.37

9.75

0.96

ol

490

0.00403

679-AL1/86-ST1A 110.0

0.042

0.36

9.95

1.15

ol

679

0.00403

490-AL1/64-ST1A 220.0

0.059

0.285

10.0

0.96

ol

490

0.00403

679-AL1/86-ST1A 220.0

0.042

0.275

11.7

1.15

ol

679

0.00403

490-AL1/64-ST1A 380.0

0.059

0.253

11.0

0.96

ol

490

0.00403

679-AL1/86-ST1A 380.0

0.042

0.25

14.6

1.15

ol

679

0.00403

Note

To add the optional column “alpha” to net.line that is used if power flow is calculated for a different line temperature than 20 °C, use the function pp.add_temperature_coefficient()

Transformers

sn_mva

vn_hv_kv

vn_lv_kv

vk_percent

vkr_percent

pfe_kw

i0_percent

shift_degree

tap_side

tap_neutral

tap_min

tap_max

tap_step_percent

tap_step_degree

tap_phase_shifter

160 MVA 380/110 kV

160.0

380.0

110.0

12.2

0.25

60.0

0.06

0

hv

0

-9

9

1.5

0

False

100 MVA 220/110 kV

100.0

220.0

110.0

12.0

0.26

55.0

0.06

0

hv

0

-9

9

1.5

0

False

63 MVA 110/20 kV

63.0

110.0

20.0

18.0

0.32

22.0

0.04

150

hv

0

-9

9

1.5

0

False

40 MVA 110/20 kV

40.0

110.0

20.0

16.2

0.34

18.0

0.05

150

hv

0

-9

9

1.5

0

False

25 MVA 110/20 kV

25.0

110.0

20.0

12.0

0.41

14.0

0.07

150

hv

0

-9

9

1.5

0

False

63 MVA 110/10 kV

63.0

110.0

10.0

18.0

0.32

22.0

0.04

150

hv

0

-9

9

1.5

0

False

40 MVA 110/10 kV

40.0

110.0

10.0

16.2

0.34

18.0

0.05

150

hv

0

-9

9

1.5

0

False

25 MVA 110/10 kV

25.0

110.0

10.0

12.0

0.41

14.0

0.07

150

hv

0

-9

9

1.5

0

False

0.25 MVA 20/0.4 kV

0.25

20.0

0.4

6.0

1.44

0.8

0.32

150

hv

0

-2

2

2.5

0

False

0.4 MVA 20/0.4 kV

0.4

20.0

0.4

6.0

1.425

1.35

0.3375

150

hv

0

-2

2

2.5

0

False

0.63 MVA 20/0.4 kV

0.63

20.0

0.4

6.0

1.206

1.65

0.2619

150

hv

0

-2

2

2.5

0

False

0.25 MVA 10/0.4 kV

0.25

10.0

0.4

4.0

1.2

0.6

0.24

150

hv

0

-2

2

2.5

0

False

0.4 MVA 10/0.4 kV

0.4

10.0

0.4

4.0

1.325

0.95

0.2375

150

hv

0

-2

2

2.5

0

False

0.63 MVA 10/0.4 kV

0.63

10.0

0.4

4.0

1.0794

1.18

0.1873

150

hv

0

-2

2

2.5

0

False

Three Winding Transformers

sn_hv_mva

sn_mv_mva

sn_lv_mva

vn_hv_kv

vn_mv_kv

vn_lv_kv

vk_hv_percent

vk_mv_percent

vk_lv_percent

vkr_hv_percent

vkr_mv_percent

vkr_lv_percent

pfe_kw

i0_percent

shift_mv_degree

shift_lv_degree

tap_side

tap_neutral

tap_min

tap_max

tap_step_percent

63/25/38 MVA 110/20/10 kV

63

25

38

110

20

10

10.4

10.4

10.4

0.28

0.32

0.35

35

0.89

0

0

hv

0

-10

10

1.2

63/25/38 MVA 110/10/10 kV

63

25

38

110

10

10

10.4

10.4

10.4

0.28

0.32

0.35

35

0.89

0

0

hv

0

-10

10

1.2